Overview
SpinFire Ultimate 11.7.1 adds support for importers including Catia v5 R29 as well as fixing issues.
Special Note
If a floating license server is already installed, you must update it to the latest Floating License Manager in order to be able to use SpinFire 11.7.1 . Simply follow the instructions here to upgrade the existing Floating License Manager.
Notable Changes
- Importer Updates
Importer Versions Supported Autodesk AutoCAD 2.5 to 2019 (2D and 3D) Autodesk Inventor Up to 2020 (3D) CATIA V5 R10 to R29 (V5-6R2019) (2D), Up to V5-6 R2019 (R29) (3D) CATIA V6 R2010x to R2019x (2D) Up to 2018x (3D) Parasolid Up to 31.1 ProE & Creo 2000i to Creo 6.0 (2D), Pro/Engineer 19.0 to Creo 6.0 (3D) SAT Up to 2019
Additional Enhancements
Performance
Improve performance of loading surfaces when Load Surfaces on Demand is enabled.
Bug Fixes
- 2D Models
- Line start/end caps and joins are wrong when their values are Round.
- NX 12 drawing has some incorrect colors and missing geometry.
- (Specific) NX file does not open.
- Arrowheads are missing from 2D NX file.
- EMF text alignment is incorrect.
- A line join of an HPGL file is incorrect.
- Font is rendered incorrectly when opening a CATDrawing.
- 2D DWFx file has wrong colors.
- 2D Tools
- Highlighted area is not rotated when rotating a selected Shape.
- Right red border is missing when adding a 2D Note.
- 3D Models
- Weld symbol information is missing from NX files.
- JT 9.5 files do not open.
- Extra geometry appears when opening some CATIA V5 assemblies.
- NX file has incorrect geometry.
- "Must specify valid key" error occurs when trying to open a CATPart.
- Missing colors from 3D DWFx file.
- Assembly Tree
- The text box context menu items are always disabled when trying to rename an assembly tree item.
- Bounding Box
- Bounding box markup corners are no longer selectable.
- Conversion
- Access Denied error occurs when trying to convert a file in some folders with sufficient permissions.
- Coordinates System
- When using a custom coordinate system and hovering over a point to perform a Point Coordinates measurement the displayed value is based on the global coordinate system.
- Exploded Assembly
- Opening the Explode Assembly window and dragging its Percentage slider is much slower than before.
- Licensing
- The License.al file is not updated when SpinFire starts, after changing sfpflv2.dat in the license server.
- Snapshots
- Impossible to drag a line created on a snapshot.
- Sectioning
- Incorrect section cut geometry for some assembly items.
- Cross-hairs stay visible after finishing creating Offset Section.
- Cross-hairs remain after finishing Offset Section selection.
- The cross-hairs to set an offset section remain on the screen.
- Selection
- Selected part disappears in viewer after focus was changed from another application.
- Thickness Measurement
- Impossible to calculate thickness sometimes when both selection and intersection points belong to the same surface.
- UI
- The Axis Triad letters are too big in 3D Preview in windows explorer.
- The Axis Triad letters appear too large when exporting an image or inserting it to an MS Office document.
- Navigation cube rotation is not consistent when using multiple clicks.
- Some dockable windows are missing after disabling Show Only Graphics mode when Viewer has multiple Documents.
- SpinFire freezes after holding F11.
- Error message is displayed when opening workspace with multiple documents, undocking an anchorable panel and switching between documents.
- Undocked Workspace toolbar is resized incorrectly after adding a new 3D Document and closing it.
- Win32Exception occurs after resetting layout and multiple viewer instances exist.
- Empty undocked panel is displayed after changing application theme and disabling the undocked panel.
- After entering Full Screen mode, saving and opening the ACT3D file, the Explorer is not visible.
- Cannot open context menu in search text box.
- The context menu of search text box has incorrect style when using Modern themes.
- Error occurs when undocking Explorer, creating a New 3D Document and changing application theme.
- Viewer crashes after pressing Ctrl+S immediately after Ctrl+C.
- Layout is not reset in non-active documents of multi-document viewer instance.
Upgrading from 11.6.4 to 11.7.1
To upgrade SpinFire Ultimate from 11.6.4 to 11.7.1
- Launch and run the SpinFire.x64.msi (or the SpinFire.x64.exe) and follow the installation wizard instructions.
or
- Select Check for Updates from the Help menu if you have an Internet connection and are upgrading form 11.1 or greater.
See SpinFire Ultimate Known Issues
Recommended Environments
Client Environment | Minimum | Recommended | Optimum |
---|---|---|---|
Operating System | Windows 7 (64-bit) SP1 | Windows 8.1 (64-bit) | Windows 10 (64-bit) |
OS Language Supported | English (US) | English (US) | English (US) |
CPU/Processor | Intel i3 4 Core 3.8 GHz (or equivalent) | Intel i5 4 Cores 3.9 GHz (or equivalent) | Intel i7 8 Cores 4 GHz (or equivalent) |
Memory | 8 GB DDR3 | 16 GB DDR3 | 32 GB DDR3 |
Graphics | DirectX 12 capable graphics card, 2GB VRAM | DirectX 12 capable graphics card, 4GB VRAM | DirectX 12 capable graphics card, 6GB VRAM |
Prerequisite Installations
- Microsoft .NET Framework 4.6.2
https://www.microsoft.com/en-us/download/details.aspx?id=53344 (Note - Already included in Windows 10)