Wall Thickness Analysis
Discovery changes in thickness of parts using the Wall Thickness Analysis tool. One can quickly determine if parts are too thick or too thin with the color washing of the model.
To use the wall thickness analysis tool:
- Select Wall Thickness Analysis from the 3D tool bar.
- Enter a refinement level.
- Set the coloring options.
- Select parts to analyze.
- Click Analyze.
- Save the analysis for later review in a user view by clicking Create User View.
Refinement Level
Change the refinement level to produce a more accurate analysis of the wall thickness. Note that increasing the refinement will increase the time it takes to complete the analysis.
Refinement Level 1 Example
However, a greater refinement level may generate a far more accurate picture for the wall thickness revealing a cleaner and sharper view of the analysis.
Refinement Level 5 Example
The refinement level basically changes the tessellation level of the model to produce a more accurate analysis. One can observe the tessellation change by viewing the model in wire mesh mode after the analysis.
Color Options
Enter the range of thickness values for the color representation.
Change any of the five main color gradients as well as the two that represent off the lower spectrum and off the upper spectrum
Select Parts
Choose to analyze all parts of the model or selected parts.
To select parts:
- Click the Parts radio button.
- Click the Select button to begin selection.
- Click on parts in the graphical area to add to the select set list.
- Click Stop select.
To remove an item from the list:
- Select an item in the list.
- Click the Remove button.
or
- Click the Clear button to remove all parts.