Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Overview

SpinFire Ultimate 11.2 contains additional features found in 10.0 that were not included in 11.0 along with a number of bug fixes.

SpinFire Ultimate will contain all the features of SpinFire 10.0 but in a phased release approach. Please see the SpinFire Matrix for more information.

Added Features

  • Model Compare
  • Draft Angle Analysis
  • Offset Sectioning (stepped sectioning)
  • 3D Mouse support
  • Two Edge Intersection Point measurement
  • 2D Stamps
  • Camera rotation undo/redo
  • 3D auto-spinning

Improved Features

  • More automated method of selecting surfaces of a void.
  • Make Void Volume Work For Holes With Planar Regions
  • Implement importing user views from ACT3D files.
  • Improved performance loading 2D AutoCAD files
  • Improved handling long paths and file names
  • Implement keyboard navigation on the Assembly tree
  • Convert models to more file types (3D PDF, ACIS, HSF, IGES, JT, Parasolid, PRC, STEP, STL, U3D and VRML)
  • Allow selection of tube axis points and edges for subsequent markup
  • Allow user to select 'Apply to all' option when multiple files are missing on load
  • Add option to bypass all missing parts when importing subassemblies
  • Add a new connection from folder search results in the library.
  • Allow user to start conversion from the library.
  • Support for direct opening of EMF files
  • Import multiple document files
  • Support of templates to export data from Parts List to an Excel file
  • Focus on Plane
  • -
  • App toolbar on right side of title bar is too obscure.

Bug Fixes 

  • Document Explorer "Name" column auto resizes to first level icons and not to the item labels
  • SF crashes after Save As with long path or file name for Event Log
  • Displaying of resize cursor for windows with fixed size
  • Missing vertical scroll bar for Description and Comment fields for markups
  • Import and export of color palettes don't support long path (>260 symbols)
  • Import and export of Materials don't support long path (>260 symbols)
  • Files aren't displayed for network connection with long file path
  • Colors are missing when changing render modes on parts from Hidden Lines Removed
  • Incorrect keyboard navigation in the viewer with arrow buttons
  • The entire assembly becomes visible after deleting a mark up.
  • Impossible to work with SpinFire after All Options dialog was collapsed
  • Change Server Parameters dialog window opens as separate window
  • Scroll doesn't follow actions in Transform dialog Handles tab
  • Starting Ultimate Reader with commandline
  • Assembly Tree in Parts List contains empty assembly items when Parts List was opened after Import Subassemblies
  • Document crashes when export to 3D PDF was started
  • Failed to import AutoCAD files with import option from File application menu
  • Impossible to use Filters without CAD views
  • View is reset after deleting a markup
  • Accent option isn't translated dynamically after changing Language option
  • Incorrect measuring of Tube Length for arcs (circles) located in the same plane
  • Impossible to close error message in specific case
  • Transparent part isn't transparent when is changed transparency of neighboring part
  • Symbol '~' replaces part of path for Print Preview option when path to template is long (>260 symbols)
  • Incorrect distance changing when Exploded Assembly option is applied
  • Select button isn't pressed by default for Select Part option in Exploded Assembly
  • Parts aren't highlighted after explode
  • Keep Viewer Aspect Ratio option doesn't consider model proportions
  • Tooltip isn't changed for Hide/Show Explorer button
  • Default selected button isn't changed in message box
  • Asterisk isn't displayed after Color and Render Mode was changed
  • Incorrect View by Plane after part was transformed
  • Focus is lost after opening dialog windows with keyboard
  • Save, E-mail and Help commands aren't focused with keyboard
  • Label “Filters” in context menu for CAD Views disappears when change the theme to Dark
  • Label color isn't changed to white after selection in Filter dialog
  • Translation is missing for Table Font style in Templates Editor
  • Filters aren't applied if Filters dialog was opened for not selected CAD View
  • Part Properties Dialog not Showing all the Lines
  • Chinese symbols are displayed incorrectly in assembly Properties
  • Profile color option does not work.
  • Spaces are missing in Assembly Tree context menu
  • Part of Assembly context menu isn't translated dynamically after language was changed
  • Double confirmation dialog appears when is saved txt file with existing name in Parts List
  • Localization is missing for exported tube data file
  • The Build number incorrectly appears as 0000 when SF11 does not have an active license.
  • The license file text does not change to the correct language.
  • Border selection is available when mouse cursor on scroll bar
  • View isn't applied to model after selection with keyboard
  • Unexpected item is selected in Assembly Tree with End button in specific case
  • Activate Coordinate system with Double Click
  • Calculate surface area in a user defined view
  • Spaces are missing for layers list in Filters dialog
  • Possible to add a markup to user view several times in specific case
  • Add context menu item to draw edge lines in intersection point markup
  • Color Palettes dialog crashes after removing all color palettes
  • Opened document don't become active in specific case
  • Custom color palettes aren't saved after the application is closed
  • None isn't translated in selected Color Palette dynamically after language was changed
  • Dialog stretches when input big name for new Coordinate System
  • Exception occurs when add place holder for non-existent variable in Translations Editor
  • Possible To Incorrectly Display Hidden Markup Geometry
  • Incorrect file path is displayed for files with long file path on Home page and tooltips
  • Tab is stretched a lot when file has long file name
  • Focus on PMI Annotation and Annotation Plane
  • Viewer context menu isn't translated dynamically after language was changed
  • Style is missing for window commands menu in Modern theme
  • Line artifacts when changing views
  • Scroll is displayed in Color dialog in Modern Theme
  • Impossible to remove color in new palette in Color Palettes dialog
  • 3D PDF Export is not correct
  • Error message contains Yes/No buttons instead OK
  • Multiselection in viewer works incorrectly
  • Warning message is missing in About window when theme of App is Modern Light
  • Drag and Drop into the same document is missing
  • Templates Editor crashes in specific case
  • File isn't opened after drag and drop file from Explorer to SF Viewer
  • Shadow isn't disappeared after drag&drop model tabs in specific case
  • Impossible to Export file when file is exported to long network path
  • Confirmation is duplicated for Export file dialog in any file type
  • Window commands menu stops working for SF after the menu was used for another dialog“
  • Error message is displayed when opening document which contains two (or more) models with equal names
  • Properties window could be decreased a lot
  • Assembly Tree disappears from Parts List when hide Assembly and reopen the dialog
  • Incorrect color of text in Parts List
  • Changes in the Translation Editor are lost after switching languages.
  • Focus is returned incorrectly
  • Impossible to uncheck documents from the list in Add Workspace Document
  • Ok button isn't disabled when all models are not checked in Add Workspace Documents dialog
  • Graphics Rendering is Missing Pieces of the File when in Zoom Fit
  • Translations Required for Installation Activation Dialog and Responses
  • Checkmarks are flashing while subassemblies are reloaded
  • Gradient background isn't stretched under application menu
  • SF crashes when work with dialog where separator “|” was deleted from translation by user
  • Transparency isn't applied to Scene dynamically
  • Markups load incorrectly
  • SF crashes when open dialog window with translation which contains double '{' symbol
  • Mark ups are not associated with created user views if a user view is first saved without any.
  • Coordinate system icon is blackout in markup label
  • SF crashes when change Page Type


  • Assembly Tree*

    • Extra nodes in the assembly tree need to be clean up/removed.

    • Spaces are missing in Assembly Tree context menu
    • SolidWorks importing with too many subassembly levels
    • Impossible to select surface using assembly tree for Minimum Distance Between Two Surfaces measurement

    • -
    • Assembly Tree items and title is not translated dynamically after changing the language option
  • Conversion

    • Red fill is missed for failed status of conversion
    • Original file is opened by double click on it's name in conversion list instead converted
    • Add file filter to Converter open file dialog
    • Conversion process does not stop when spinfire was closed after conversion is failed
    • Error message is displayed if conversion process tries to overwrite existing file which is blocked
    • Converter process isn't ended in Task Manager when Remove item from conversion list while conversion is in progress
    • Convert button is enabled when no file type is checked
    • Conversion dialog is closed when press No button in confirmation dialog
    • Add support of very long paths and file names to Convert
    • Incorrect message in confirmation dialog for Converter
    • Item is deleted from Conversion list when close confirmation dialog using cross button
    • Impossible to convert model with annotation to 3D PDF
    • Incorrect indexes appear in conversion list
  • Coordinate Systems*

    • Activate Coordinate system with Double Click
    • Creating New Coordinate System Leaves Ghost Circle

  • Export

    • SF crashes after Export file with long path or file name for Translations Editor
  • Export Image*

    • Export to Image or Hard Copy Creating Very Large Unusable Files

    Library
    • Incorrect sorting of File list in Library

  • Import
    • Implement importing user views from ACT3D files.
    • Proceed” button isn't disabled when all Actions are set as None in Import Files dialog
    • Import in 2D model does not work
    • Spaces are missing in Import Files dialog when there are lots of files in list
    • Horizontal scroll bar is displayed for Import Files dialog when the theme of application is Classic
    • Nothing happens when drag & drop document from Explorer to Viewer where 2D document is active
  • Library
    • Key in alphanumeric to go to corresponding folder in library
    • File list isn't displayed after selecting folder in Library with keyboard
    • Key in alphanumeric to go to corresponding folder in library
    Measurements
    • *Remove the bend center points that remain after performing a tube length measurement.-
    • Incorrect sorting of File list in Library
    • Error occurs when trying to drag and drop files to a parent folder in the Library
    • Impossible to deselect files with CTRL+Left-Mouse-Button combination in Library files list
    • Scroll isn't focused on found item in Library
    • Missing support of long network file path in Library for folder tree
    • Can't drag&drop file to folder with long network folder path in Library
    • Application crashes when toggle to tiles display in Library for folder with long path
    • Library Tab is opened after pressing No in confirmation dialog related to conversion
    • Selection isn't cleared in Library files list after scrolling and reselection
    • Document is opened with double click from Library when Ctrl or Shift keyboard button is pressed
  • Measurements*
    • AutoNote does not take into account parts that have been moved (transformed).
    • AutoNote dialog dismisses upon completion.
    • The measurement dialogs for the Minimum Bounding Box measurement have features that are not functional

    • Incorrect measuring of Tube Length for arcs (circles) located in the same plane

    • A tube length measurement doesn't finish on the specific part

    • Localization is missing for exported tube data file
    • Incorrect anchor for Mass properties and Boundary Volume by Surfaces measurement

    • Calculate surface area in a user defined view
    • 2D document crashes after adding a markup
    Misc.
    • -
    • 2D Measurements/Markups
      • 2D Boundary Center by Edges measurement allows user to select the same edge twice
      • Incorrect option name in context menu for Boundary Area by Edges measurement for 2D model
      • Unexpected calculation of Boundary Area by Points measurement for 2D model in specific case
      • 2D document crashes after adding a markup
    • 3D Measurements/Markups
      • No Longer Able to Select Axis Center Point for Dimensioning
      • Thickness measurement results appear incorrect
      • Infinity calculations on non flat surfaces for Axis Aligned Bounding box
      • Bound Box of Selected Surfaces Does not Work
      • Bounding Box Color should be defaulted to Grey, not White, as in 10.8
      • Minimum Bounding Box doesn't work on a surface.
      • Boundary Center by Edges measurement starts to work incorrectly after several uses
      • Varying Angle Measurements Based on Function Used
      • Deleted bounding box reappears when creating a new user view
      • Axis aligned bounding box for a surface is not working
      • Boundary Volume by Area Dialog Crashes on selection
      • Boundary Volume by Area Dialog Crashes on calculate
      • Stop Selection button for Blocking surfaces does not function in the Boundary Volume by Surfaces dialog
      • Make Void Volume Work For Holes With Planar Regions
      • Void volume display problem
      • Midpoint text is not visible
      • Unable to select Edges under Boundary Center by Edges and Sum of Connected Edges
      • AutoNote does not take into account parts that have been moved (transformed).
  • Misc.*
    • Report newer Windows versions during registration
    • Selecting the Email Feature sends the Original CAD File instead of the .ACT3D File
    • The license file text does not change to the correct language.
    • Null Reference Exception on closing multiple configuration file
    • Border selection is available when mouse cursor on scroll bar
    • SpinFire Ultimate Install Issue on Windows 7 32Bit

    • Starting Ultimate Reader with commandline

    • Files aren't displayed for network connection with long file path

  • Opening CAD .3D Files
    • .3D files with 2D circles and ellipses show up blank
    • .3D file with polygonal shapes rendered poorly
    • .3D file with curve-cornered rectangle renders poorly
    • .3D file with different 2D line strokes renders poorly
    • SpinFire 10.9 .3D file fails to open
    • 2D .3D read failure for CGM/TIFF files converted from SpinFire 8
    • SFU has an issue opening converted Old .3D files converted to V10 .3D files
    • SF10 markup text colors are importing as Transparent in SF11
    • Imported 3D models from multi-document files do not appear in the graphics area after reloading a saved ACT3D file.
    • .3D file converted from SpinFire8 to SpinFire10 fails to open
    • Import .3D file is missing
    • Can't open .3D model saved by long path (>260)
    • Impossible to open .3D file where Impact font is applied to a markup
    • Old .3D file causes "Object reference not set" error
    • Centro 6 created .3D files with no color background always black
    • Back color for model item imported from SF10 isn't applied in SF11
    • Render mode imported from SF10 isn't applied in SF11
    • Back color from SF10 isn't loaded correctly for Startup View in SF11
    • Support Tube Length Bend Center Points for SF10 Files
  • Opening ACT3D files
    • Cannot open .ACT3D with imported files

  • Opening CAD *
    • An extra part was loaded when using partial loading and import sub assembly on an NX assembly.
    • AutoDesk DWF takes a really long time to load
    • Improve the way to determine if a model layout in an AutoCAD file should be drawn in 2D or 3DVertically listed text is not underlined and surround by "<u>"
    • Dimensions of a CATPart with ~13000 surfaces nearly impossible
    • Allow user to select 'Apply to all' option when multiple files are missing on load
    • -
    • Taking way too long to open a small assembly
    • More than one search path is not possible in Importer options
    • AutoCAD
      • Notification is missing after exporting section cut geometry as a DXF file
      • Section "Export to DXF" must transform to the Z plane.
      • AutoDesk DWF takes a really long time to load
      • 14Mb DWG file takes a very long time to load
      • Large DWG file takes a very long time to load
      • Poor view of DWG extents and tabs
    • CATIA
      • CATIA V5 - Imported PMI Data and Section Cuts Not Being Assigned to the Imported Views Correctly
      • Unexpected rectangle element in CATIA drawing
      • Vertically listed text is not underlined and surround by "<u>"
    • CGM
      • CGM file is not displayed correctly
    • NX
      • NX is missing wireframe
      • NX - Imported PMI Data and Section Cuts Not Being Assigned to the Imported Views Correctly
      • There is extra geometry appearing in NX 2D files
      • Missing lines on NX 2D file
    • STEP
      • STEP AP242 with GDT (PMI) support
      • STEP file takes a very long time to load (TechSoft #23467)
  • Sectioning

    • Section Cut Incorrect After Turning Cut Material Off and Back On

    • Incorrect View by Plane after part was transformed-

    • Section Planes appear after switching to Default view
    • Sectioning part colors are missing
    • Section planes do not appear after partial loading an assembly.
    • Cross-section view not updated correctly after layout change.
    • Multi-plane section cut geometry is not selectable.
    • Section profile Switching into Cross-Section View is Turning off Section Plane
    • Cross Section Dynamic Update is Missing
    • The grid appears in part of the cross-section view, sometimes.
    • 3D files don't appear with sectioning when a starting user view has sectioning on.
    • Snap radius seems too big on section cut
    • Section profile color during dynamic move is different
    • Transparent parts behind section plane are not visible
    • Cross section view is incorrect with multiple views enabled
    • Move section does not work after doing a Zoom or Pan
    • Dynamic move of section without section plane
    • Profile Face Color isn't applied dynamically to Section
    • Crash when using section with load only assembly tree
    • Cutting Section Area Markup Missing Some Capping Geometry
  • Translations
    • Tooltip is cut in Translations dialog
    • Convert button for ACT3D options in Converter dialog overlaps with Reset to Default button when language is Deutsch
    • Converting status name is cropped for Deutsch language
    • SpinFire crashes when try to Save model if Application language is German
    • Import of Translation does not work when imported file is located on long file path
    • Translate suffixes for shattered files
  • UI*
    • Default selected button isn't changed in message box
    • Scroll doesn't follow actions in Transform dialog Handles tab
    • Missing support of long network file path in Library for folder tree
    • The Build number incorrectly appears as 0000 when SF11 does not have an active license.
    • Incorrect keyboard navigation in the viewer with arrow buttons
    • Color Palettes dialog crashes after removing all color palettes
    • Allow re-sizing for properties window
    • Cancel button should be replaced with Close button after Apply
    • -
    • Importer Options Cancel Button Cut Off
    • Check markers are reversed in classic theme on Windows 8
    • There's a line under the 3D toolbar that doesn't redraw/update
    • Conversion panel could overlap Library toolbar
    • Zooming too far in breaks 'Axis Triad' and 'Navigation Cube'.
  • Views*
    • Filters aren't applied if Filters dialog was opened for not selected CAD View

    • Impossible to use Filters without CAD views

Installation

SpinFire Ultimate 11.2 can be installed side-by-side with previous versions of SpinFire, such as the 10.x release. 

Upgrading from 11.0.0 to 11.1.0

To upgrade SpinFire Ultimate from 11.0 or 11.1 to 11.2:

  1. Launch and run the SpinFire.x64.msi (or the SpinFire.x64.exe) and follow the installation wizard instructions.

See SpinFire Ultimate Known Issues

Supported Environments

Client EnvironmentMinimumRecommendedOptimum
Operating System

Windows 7 (64-bit)
Windows 7 (32-bit)
Windows 8 (64-bit) 
Windows 8 (32-bit)
Windows 10 (64-bit)
Windows Server 2008 R2 (64-bit)
Windows Server 2012
 

Windows 8 (64-bit)
Windows 7 (64-bit) 
Windows 8 (64-bit)
OS Language Supported

English (US)
German
French
Italian
Spanish
Portuguese
Czech
Japanese
Chinese (simplified)
Chinese (traditional)
Korean
 

English (US)
German

English (US)
German

 

CPU/Processor

Intel i3 4 Core 4 GHz (or equivalent)

Intel i5 4 Core 4 GHz (or equivalent)

Intel i7 8 Core 4 GHz (or equivalent)

Memory4 GB8 GB16 GB
Graphics

DirectX 11 capable
graphics card, 1GB VRAM

DirectX 11 capable
graphics card, 2GB VRAM

DirectX 11 capable
graphics card, 3GB VRAM

 

Prerequisite Installations