Overview
SpinFire Ultimate 11.1 contains additional features found in 10.0 that were not included in 11.0 along with a number of bug fixes.
SpinFire Ultimate will contain all the features of SpinFire 10.0 but in a phased release approach. Please see the SpinFire Matrix for more information.
Added Features
- Import document
- Add document
- Transform by handles
- Exploded assembly
- Shattered assembly ACT3D files
- Tube length bill of materials
- Snapshots
- Calculate the area, perimeter, and centroid of a section profile
- CGM importer
- TIFF importer
- Additional language support
- Chinese (simplified)
- Chinese (traditional)
- Czech
- French
- Italian
- Japanese
- Korean
- Portuguese
- Spanish
Improved Features
- Export Part List in Excel file format
- Auto Complete option for the tube length calculation
- View files as thumbnails in the Library
- "Copy to Clipboard" option on the Export > Image dialog
- Add options to the Recent Documents context menu
- Portrait/Landscape toggle in Print Preview
- First selected surface remains highlighted for Minimum Distance Between Two Surfaces measurement
- Materials list translated to other languages
- Focus options added to context menu for 2D views.
- Another part can be selected without having to close the Properties dialog
- Section plane distance displayed along the normal
- Default CAD view added to the CAD views list
Bug Fixes
2D file formats
- The ohm symbol appears as a box in NX 2D files.
- Foreign characters do not appear in CATDrawing file.
- CATDrawing causes a crash in the SpinFire Viewer when opening.
- Incorrect scale for DXF file.
- Visibility control (hide/show) in 2D does not work.
- Some Chinese characters do not appear even when the font is available.
- Line Thickness of 2D dimension line and dimension extension line are too thick.
Incorrect displaying of CATIA drawing primitives.
CATIA V4 2D Drawing - Line width incorrect when Zoomed In or Out.
- Symbol "β" exists not for all fonts.
- Importing incorrect line thickness for 2D SLDDRW documents.
3D file formats
- An IGES file and does not zoom correctly using the navigation cube.
- Imported NX file assembly tree selection is incorrect.
- NX assembly crashes SpinFire when importing.
- NX assembly takes 4 times longer to Import than 10.8.2.
NX File imports correctly in SpinFire 10.8.2 but Not in SpinFire Ultimate.
NX notes and die draw axis symbols are not importing.
- A specific SolidWorks file fails to open.
SpinFire 10 file with an empty 3D work space and 2D drawing does not load.
- Opening a specific .3D crashes SpinFire.
- Load colors from SpinFire 10 user views.
- 2D Measurements
- 2D Notes lose the underline when adding a hyperlink.
- 3D Measurements
- Boundary Area By Edges measurement could be applied to Annotation plane.
- Hide/show surface options don't change the label correctly in context menu in Markups tree for the Boundary Area by Edges measurement.
- Status of the check mark is not updated after deletion or adding elements to any node of Markups tree.
- Bounding box markups do not respect transforms.
- Document crashes when click on markup if the markup contains incorrect hyperlink.
- Document crashes when try to open context menu for the part which was measured by Boundary Area By Edges measurement.
The first surface selected on a Distance Between Two Surfaces measurement needs to remain highlighted until the second surface is selected.
- Arc highlighting for Arc Diameter and Arc Radius remains when the measurements are disabled.
- When performing "All Subassemblies" Auto Note, some notes are not pointing at the model.
- Cannot add a hyperlink to a very long file for markup.
- Bounding box measurement properties imported from SpinFire 10 are not applied in SpinFire Ultimate.
- Chinese characters do not work in markups.
- The first selected surface is not highlighted when the user select the second surface for Minimum Distance Between Two Surfaces measurement.
Assembly Tree
“Expand All” should expand to parts level, not solids.
- Annotation plane is marked as indeterminate when all children are unchecked.
- Impossible to apply highlighted view from Views tree.
Library
Implement saving of customized displaying of file list in Library after closing application.
Scroll option in library file list is not working with mouse wheel.
Header for file list in Library is scrolled with file list.
- File search in library folder not releasing search parameter when switching folders.
- Folders are duplicated in explorer after connection was added.
- Files are duplicated in file list after connection was added.
Miscellaneous
- Intermittent crash.
- Settings.config is not removed during uninstall.
- SFXI-460 If a file(s) fails in an assembly, SpinFire should still open the model without the failed files.
Current work is lost without warning if the updater runs.
Impossible to remove items from converter list
- Allow a closing backslash on Custom Updates URL.
- Floating license file data has an expiration date, but should not
Sectioning
Do not disable features when section dialog is enabled.
Section cut by Three points is incorrect.
Section cut by Two points is incorrect.
- Selection fails after sectioning.
- Unable to select surfaces after section cut is created.
- Remove the need to "Enable Dragging".
- Profile edges appear with user views with sections.
- Attached NX assembly has strange sectioning behavior.
- Apply" should be disabled in certain section dialog scenarios.
- Measure section cut profile edges..
- Document crashes when a section is enabled and a user tries to open context menu.
- The state of the Project Mode command is not correct if disabling then re-enabling sectioning.
Selection
One cannot select parts after opening an assembly in Load Assembly Tree Only mode.
- Unhighlight selected items after performing action.
- View isn't highlighted immediately after selecting the view in drawing tree.
- Highlighted model element is missing in Print Preview after the view is refreshed.
- Transform
- Zoom Fit doesn't work after transforming a part.
- Transform dialog is displayed out of SpinFire Ultimate window.
- Bounding box markups do not respect transforms.
- UI
- Message boxes should be dismissed via ESC key.
- The "What's New" link on the Home page in German has an invalid link.
- Information boxes and dialog windows for viewer don't block access to application.
- Shift+right-click part selection in the graphic window does not allow to hide form the context menu.
- Apply, Ok and Cancel buttons are not disabled during Preview on the Transform dialog.
- Add Markup to All Views option is active after it was selected before.
- Yellow polyline is visible in case user unticks a 'Stay on Top' functionality.
Hyperlink to a view during note creation does not work.
- Hyperlink fields don't support files with long file name or path(>260).
- Incorrect coordinate positions for new coordinate system.
- Sorting doesn't work on 'Select document and User View' window.
- Viewports button isn't highlighted after pressing on it as it is in SpinFire 10.
- Assembly item is counted incorrectly in Parts List for specific model
- Incorrect validation of Selected Color Palette value after apply in Color Palettes dialog.
- Annotation plane is marked as indeterminate when all children are unchecked.
Installation
SpinFire Ultimate 11.1- Model Compare
- Draft Angle Analysis
- Offset Sectioning (stepped sectioning)
- 3D Mouse support
- Two Edge Intersection Point measurement
- Thickness by Color
- Importer: SolidEdge 2D
Improved Features
- More automated method of selecting surfaces of a void.
- Make Void Volume Work For Holes With Planar Regions
- Implement importing user views from ACT3D files.
- Improved performance loading 2D AutoCAD files
- Improved handling long paths and file names
- Implement keyboard navigation on the Assembly tree
- Convert models to more file types (3D PDF, ACIS, HSF, IGES, JT, Parasolid, PRC, STEP, STL, U3D and VRML)
- Allow selection of tube axis points and edges for subsequent markup
- Allow user to select 'Apply to all' option when multiple files are missing on load
- Add option to bypass all missing parts when importing subassemblies
- Add Connection after search folder in library
- Support for direct opening of EMF files
Bug Fixes
Extra nodes in the assembly tree need to be clean up/removed.
- Report newer Windows versions during registration
- Default selected button isn't changed in message box
- Selecting the Email Feature sends the Original CAD File instead of the .ACT3D File
- *Remove the bend center points that remain after performing a tube length measurement.
- Incorrect sorting of File list in Library
Filters aren't applied if Filters dialog was opened for not selected CAD View
Spaces are missing in Assembly Tree context menu
The license file text does not change to the correct language.
AutoNote does not take into account parts that have been moved (transformed).
An extra part was loaded when using partial loading and import sub assembly on an NX assembly.
The measurement dialogs for the Minimum Bounding Box measurement have features that are not functional
SolidWorks Importing with Too many Subassembly Levels
Null Reference Exception on closing multiple configuration file
Export to Image or Hard Copy Creating Very Large Unusable Files
Dimensions of a CATPart with ~13000 surfaces nearly impossible
Section Cut Incorrect After Turning Cut Material Off and Back On
Incorrect measuring of Tube Length for arcs (circles) located in the same plane
A tube length measurement doesn't finish on the specific part
Incorrect anchor for Mass properties and Boundary Volume by Surfaces measurement
Incorrect View by Plane after part was transformed
Scroll doesn't follow actions in Transform dialog Handles tab
Impossible to select surface using Assembly Tree for Minimum Distance Between Two Surfaces measurement
Missing support of long network file path in Library for folder tree
File list isn't displayed after selecting folder in Library with keyboard
Border selection is available when mouse cursor on scroll bar
The Build number incorrectly appears as 0000 when SF11 does not have an active license.
Impossible to use Filters without CAD views
Incorrect keyboard navigation in the viewer with arrow buttons
Section profile color during dynamic move is different
Localization is missing for exported tube data file
SpinFire Ultimate Install Issue on Windows 7 32Bit
Calculate surface area in a user defined view
Activate Coordinate system with Double Click
Starting Ultimate Reader with commandline
Vertically listed text is not underlined and surround by "<u>"
AutoDesk DWF takes a really long time to load
2D document crashes after adding a markup
Files aren't displayed for network connection with long file path
Color Palettes dialog crashes after removing all color palettes
Creating New Coordinate System Leaves Ghost Circle
Installation
SpinFire Ultimate 11.2 can be installed side-by-side with previous versions of SpinFire, such as the 10.x release.
Upgrading from 11.0.0 to 11.1.0
To upgrade SpinFire Ultimate from 11.0 or 11.1 to 11.12:
- Launch and run the SpinFire.x64.msi (or the SpinFire.x64.exe) and follow the installation wizard instructions.
Supported Environments
Client Environment | Minimum | Recommended | Optimum |
---|---|---|---|
Operating System | Windows 7 (64-bit) | Windows 8 (64-bit) Windows 7 (64-bit) | Windows 8 (64-bit) |
OS Language Supported | English (US) | English (US) | English (US)
|
CPU/Processor | Intel i3 4 Core 4 GHz (or equivalent) | Intel i5 4 Core 4 GHz (or equivalent) | Intel i7 8 Core 4 GHz (or equivalent) |
Memory | 4 GB | 8 GB | 16 GB |
Graphics | DirectX 11 capable | DirectX 11 capable | DirectX 11 capable |
Prerequisite Installations
- Microsoft .NET Framework 4.5
https://www.microsoft.com/en-us/download/details.aspx?id=40784 (Note - Already included in Windows 8 )